Page 23 - ENT IMPLANTS CATALOGUE IMPLANTS ORL
P. 23

MRP MALLEUS REPLACEMENT PROSTHESIS







                STABILITY FOR A LONG-LASTING OUTCOME
                Postoperative movements of the tympanic membrane can have a
                negative effect on the optimal position of a middle ear prosthe-
                sis. Invasive disease and anteriorly positioned malleus add to the
                degree of difficulty to reconstruction.
                One of the aims of ossicular chain reconstruction is consequently
                to create a stable reconstruction minimizing the risk of tilting of the
                prosthesis.

                SIMULATES AN ABSENT MANUBRIUM OF MALLEUS
                The Malleus Replacement Prosthesis delivers an innovative con-
                cept which may considerably improve reconstruction instability of
                prostheses by creating an accessible lateral platform for implants
                to couple to. The adjustable Y link can be optimally positioned to
                the bony rim of the auditory canal.

                WIDE RANGE OF APPLICATIONS
                The MRP stabilizes and secures a partial or total reconstruction
                and counteracts dislocation, especially during the initial healing
                phase. It can be used in conjunction with a large number of KURZ
                prostheses. Ideally it is suited to interface with the Malleus Notch
                Prosthesis or the Cavity Bending Pliers (see page 54). The latter
                can easily be used on various KURZ prosthesis head plates.
                Developed in close collaboration with Dr. Robert Vincent, Béziers
                (Causse Ear Clinic), France.






                                                                                         External
                                                                                         Canal Wall



                                          NOT AVAILABLE FOR SALE IN THE USA

                                               ITEM            REF

               ø 0.80 mm                       MRP Ø 0.8 x 3.0 mm  1006 960

                                        3.0 mm

                     3.0 mm
                         6.25 mm


                                  80°
                                       1.30

                                     ø 0.40 mm
               MRP Prosthesis
               Material:
               Pure Titanium (ASTM F67
               Medical Grade)